Sale!

Electric Centrifuge Machine Lab Medical Practice 110V 800-1 4000 rpm Lower-speed

$23.75

211

  • UPC: 0700161265859
  • Item must be returned within: 60 Days
  • Refund will be given as: Money back or replacement (buyer's choice)
  • MPN: Does not apply
  • All returns accepted: Returns Accepted
  • Brand: Unbranded
  • Condition: New
  • Restocking Fee: No
  • Return shipping will be paid by: Seller

Description

Product description
Lower-speed
Centrifugal Machine is mainly used to separate suspension of solid
particles and liquid; Or emulsion in the two kinds of different density
and mutual miscibility of liquid separation (such as isolated from milk
cream); It can also be used to eliminate wet solid in the liquid, such
as use washing machine to jilt dry wet clothes; Special speed tubular
can separate different density of gas mixture, such as enrichment and
separation of gaseous uranium hexafluoride: With different density and
particle size of solid particles in a liquid sedimentation velocity of
different characteristics, some sedimentation centrifuge for solid
particles according to density and grain size grading.
Instruction:
The
table-centrifugal machines are widely used in the laboratory or produce
department fororganisms、 medical、 chemistry etc. The lower speed
centrifugal machine with the maximum speed 4000r/min and be equipped
with/without timer. It mainly be used for the appraisal radioactivity
and separate cell or particle.
Specification:
Model
Maximum
speed
Capacity
Maximum relative
Centrifugal force
Time rang
Electric current
800-1
4000r/min
20ml
×
6
1790
×g
0
~60min.or
without limit
AC110V 60 HZ
80-2
4000r/min
20ml
×12
2380
×g
0
~60min.or
without limit
AC110V 60HZ
Operation:
Put
the machine on a level and strong table and keep the working room clear
、dry and ventilated .Indoor temperture5- 32℃ is ok Open the power
supply and make sure the indicator lamp is light .Shut the power switch.
Open the cover of the machine, clear the rotor and container. Put the
test tube (with same weight) into the machine .put down the cover of the
machine .Adjust the timer as your requirement. Open the power switch.
Adjust the governor as you requirement. Before you are going to stop the
work, you should adjust the governor to “0”fist, and then shut the
power supply .Clean the container and rotor, then put down the cover.
Safety Warning:
After
you open the power switch, please shut the power supply and make an
examination if the indicators not light Do not operate the machine the
machine without rotor . When you are going to operate the machine, you
should make the rotor is not corroded/hurt. Do not open the cover of the
machine and touch the rotor when the rotor when the rotor is in moving.
Do not operate the machine if the rotor is not balance assembled.
Safeguard and Maintain:
Do
not put anything on the cover. After using, please clean the rotor and
container, and put down the cover to keep the pollutant out If the
machine have not been used for a long time ,please open the cover and
dry the container before you are going to use again. If the carbon brush
of the motor have been over 3000 hours, please change the brush avoid
hurt of commentator . if the machine have been used for a long time
natural weal and tear is normal our products are one your warrant and we
can continue give you a good after-sale service after one year.
We
can supply the machine with customer’s special specification .And price
to be negotiated .For inquiry, please contact with our head-office and
branch-office.